Winter, Alexander and Engels, Svenja and Goos, Philipp and Süykers, Marie-Christin and Gudenkauf, Stefan and Henke, Rolf-Peter and Wawroschek, Friedhelm (2019) Accuracy of Magnetometer-Guided Sentinel Lymphadenectomy after Intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles in Prostate Cancer: The SentiMag Pro II Study. Cancers, 12 (1). p. 32. ISSN 2072-6694

[img]
Preview
- Published Version

Volltext (654Kb)

Abstract

Radioisotope-guided sentinel lymph node dissection (sLND) has shown high diagnostic reliability in prostate (PCa) and other cancers. To overcome the limitations of the radioactive tracers, magnetometer-guided sLND using superparamagnetic iron oxide nanoparticles (SPIONs) has been successfully used in PCa. This prospective study (SentiMag Pro II, DRKS00007671) determined the diagnostic accuracy of magnetometer-guided sLND in intermediate- and high-risk PCa. Fifty intermediate- or high-risk PCa patients (prostate-specific antigen (PSA) ≥ 10 ng/mL and/or Gleason score ≥ 7; median PSA 10.8 ng/mL, IQR 7.4–19.2 ng/mL) were enrolled. After the intraprostatic SPIONs injection a day earlier, patients underwent magnetometer-guided sLND and extended lymph node dissection (eLND, followed by radical prostatectomy. SLNs were detected in in vivo and in ex vivo samples. Diagnostic accuracy of sLND was assessed using eLND as the reference. SLNs were detected in all patients (detection rate 100%), with 447 sentinel lymph nodes SLNs (median 9, IQR 6–12) being identified and 966 LNs (median 18, IQR 15–23) being removed. Thirty-six percent (18/50) of patients had LN metastases (median 2, IQR 1–3). Magnetometer-guided sLND had 100% sensitivity, 97.0% specificity, 94.4% positive predictive value, 100% negative predictive value, 0.0% false negative rate, and 3.0% additional diagnostic value (LN metastases only in SLNs outside the eLND template). In vivo, one positive SLN/LN-positive patient was missed, resulting in a sensitivity of 94.4%. In conclusion, this new magnetic sentinel procedure has high accuracy for nodal staging in intermediate- and high-risk PCa. The reliability of intraoperative SLN detection using this magnetometer system requires verification in further multicentric studies.

Item Type: Article
Additional Information: Publiziert mit Hilfe des DFG-geförderten Open Access-Publikationsfonds der Carl von Ossietzky Universität Oldenburg.
Uncontrolled Keywords: lymphadenectomy, magnetometer, prostate cancer, sentinel lymph node dissection, SPION, superparamagnetic iron oxide nanoparticles
Subjects: Technology, medicine, applied sciences > Medicine and health
Divisions: Faculty of Medicine and Health Sciences > Department of Human Medicine
Date Deposited: 20 Mar 2020 11:46
Last Modified: 20 Mar 2020 11:46
URI: https://oops.uni-oldenburg.de/id/eprint/4546
URN: urn:nbn:de:gbv:715-oops-46279
DOI: 10.3390/cancers12010032
Nutzungslizenz:

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...